The TY-SXD2 series of single-phase electric energy metering boxes, including models TY-SXD2-9B, TY-SXD2-9C, TY-SXD2-10B, TY-SXD2-12B, TY-SXD2-15A, and TY-SXD2-18A, stands out for its exceptional insulation performance. Manufactured by reputable China suppliers, these control boxes utilize high-quality glass fiber reinforced plastic, ensuring reliable insulation suitable for various electrical applications. This feature is crucial in residential settings where safety is a top priority. The strong material not only enhances durability but also prolongs product life, enabling it to endure daily wear and tear without sacrificing performance. Our factory is dedicated to providing high-quality metering solutions that meet the demands of today's electrical systems.

    Product Overview

    The TY series FRP electric energy metering boxes developed by Teyi Electric Co., Ltd. are made of SMC unsaturated polyester resin glass fiber reinforced plastics through compression molding. They have the characteristics of reliable insulation, high strength, good flame retardancy, corrosion resistance, aging resistance, novel shape, smooth and beautiful surface, etc. The service life is more than 40 years indoors and more than 30 years outdoors, which is incomparable to other metal plastic electric meter boxes. This product is widely used in residential construction and civil power transformation. It can be combined with multiple households at will, and can also be installed in a single household or across households. It is easy to construct and has concealed wiring. This product adopts a strict rainproof design and is suitable for outdoor installation to ensure the safe operation of the electric meter.

    Product use scope and conditions of use

    TY series electric energy metering box includes two parts: single-phase meter box and three-phase meter box. It is suitable for AC 50Hz or 60Hz, rated working voltage up to 220V, 380V, 690V, rated working current of 10A-250A power supply system, for single-phase electric energy and power energy measurement and control management.

    Conditions of use:

    • The ambient temperature is -25℃ ~+50℃, and the average temperature within 24 hours does not exceed +35℃.
    • The air should be clean, and the relative humidity should not exceed 80% at 40℃. Higher relative humidity is allowed when the temperature is lower.

    Product installation and use

    • Please carefully check the integrity of all parts of the meter box during installation.
    • The meter box should be installed vertically and the tilt angle should not exceed 54°.
    • The installation location should be selected where there is no severe vibration, impact, or corrosion to electrical components.
    • The material used in the meter box is not resistant to strong alkali, oxidizing acid, amine, ketone, and soluble in chlorinated hydrocarbons and aromatic solvents. Therefore, it should be avoided from contact or use with these chemicals. During use, sharp objects and hard objects should be avoided from colliding and scratching the surface of the meter box.
    • When installing the meter box, try to choose a cool and dry place to avoid long-term direct sunlight to extend the service life of the meter.
    • The fixing positions of the meter box for fixing on the wall or crossarm are all located inward, so the box must be opened before installation. First, remove the two upper cover fixing screws located in the middle of the lower part of the meter box, and then open the box according to the instructions here.
    • According to the location of the installation holes, drill the installation holes at the corresponding positions of the wall, install the expansion tube, then fix the base to the wall and install the upper cover.

    Main technical parameters of the product

    Main bus rated current In 250A-10A
    Main bus rated short-time withstand current low 30KA
    Insulation resistance not less than 20MΩ
    Rated insulation voltage UI 800V
    Frequency 50Hz or 60Hz
    Security protection level IP 44

    Model, configuration and installation dimensions

    TY-SXD2-9B

    TY SX D2 9 B
    Company Code SMC non-metallic metering box Single-phase multi-meter metering box Table number Second Generation
    Configuration Name Component Model Quantity
    Incoming switch Incoming line isolation HGL-200/3 1
    breaker Molded case circuit breaker CDMK-250C/3300 200A 1
    Outlet switch Miniature circuit breakers CDBKs C type 2P 63A dedicated to power grid 9
    TY-SXD2-9B.jpg

    TY-SXD2-9C

    TY SX D2 9 C
    Company Code SMC non-metallic metering box Single-phase multi-meter metering box Table number Third Generation
    Configuration Name Component Model Quantity
    Incoming switch Molded case circuit breaker CDMK-250C/3300 200A 1
    Outlet switch Miniature circuit breakers CDBKs C type 2P 63A dedicated to power grid 9
    TY-SXD2-9C.jpg

    TY-SXD2-10B

    TY SX D2 10 B
    Company Code SMC non-metallic metering box Single-phase multi-meter metering box Table number Second Generation
    Configuration Name Component Model Quantity
    Incoming switch Molded case circuit breaker CDMK-250C/3300 200A 1
    Outlet switch Miniature circuit breakers CDBKs C type 2P 63A dedicated to power grid 10
    TY-SXD2-9B.jpg

    TY-SXD2-12B

    TY SX D2 12 B
    Company Code SMC non-metallic metering box Single-phase multi-meter metering box Table number Second Generation
    Configuration Name Component Model Quantity
    Incoming switch Molded case circuit breaker CDMK-250C/3300 200A 1
    Outlet switch Miniature circuit breakers CDBKs C type 2P 63A dedicated to power grid 12
    TY-SXD2-12B.jpg

    TY-SXD2-15A

    TY SX D2 15 A
    Company Code SMC non-metallic metering box Single-phase multi-meter metering box Table number First Generation
    Configuration Name Component Model Quantity
    Incoming switch Molded case circuit breaker CDMK-250C/3300 200A 1
    Outlet switch Miniature circuit breakers CDBKs C type 2P 63A dedicated to power grid 15
    Power supply breaker breaker CDBK C type 2P 6A 1
    TY-SXD2-15A.jpg

    TY-SXD2-18A

    TY SX D2 18 A
    Company Code SMC non-metallic metering box Single-phase multi-meter metering box Table number First Generation
    Configuration Name Component Model Quantity
    Incoming switch Molded case circuit breaker CDMK-250C/3300 250A 1
    Outlet switch Miniature circuit breakers CDBKs C type 2P 63A dedicated to power grid 18
    Power supply breaker breaker CDBK C type 2P 6A 1
    TY-SXD2-18A.jpg

    Frequently Asked Questions (FAQ)

    What material is the TY series electric energy metering box made of?
    The TY series electric energy metering boxes are made of SMC (Sheet Molding Compound) unsaturated polyester resin glass fiber reinforced plastics through compression molding.
    What is the expected service life of these metering boxes?
    They offer an exceptionally long service life of more than 40 years for indoor installations and more than 30 years for outdoor installations.
    What are the main environmental conditions required for installation?
    The ambient temperature should be between -25℃ and +50℃ (with a 24-hour average not exceeding +35℃). The air should be clean, and relative humidity must not exceed 80% at 40℃ (higher relative humidity is acceptable at lower temperatures).
    What chemicals should be kept away from the meter box?
    The SMC material is not resistant to strong alkalis, oxidizing acids, amines, ketones, and is soluble in chlorinated hydrocarbons and aromatic solvents. Avoid contact with these substances to prevent degradation.
    What is the IP security protection level of these boxes?
    The TY series electric energy metering boxes feature a security protection level of IP44, adopting a strict rainproof design suitable for outdoor use.
    How should the box be mounted and positioned?
    The meter box must be installed vertically with a tilt angle not exceeding 54°. It should be placed in a cool, dry area away from direct sunlight, severe vibrations, impact, or corrosive environments.