Introducing the TY series three-phase one-digit electricity meter boxes, including models TY-SXS1-1H, TY-SXS1-NX1, TY-SXS1-1B, TY-SXS1-1C, TY-SXS1-1D, and TY-SXS1-1E. Manufactured in China, these high-quality solutions are designed by reliable suppliers and factories to ensure unparalleled safety and reliability. With an insulation resistance of no less than 20MΩ and a rated insulation voltage of 800V, these meter boxes effectively meet the demands of modern electrical systems. They are compatible with both 50Hz and 60Hz frequencies, making them versatile for various applications. Additionally, the IP 44 safety protection level offers excellent dust and water resistance, ensuring their durability across different environments. Choose our TY series electricity meter boxes for your electrical needs, backed by trusted Chinese manufacturing expertise

    Features Summary
    Excellent Material

    SMC glass fiber reinforced plastic molding, featuring high insulation (≥20MΩ), high impact resistance (30KA short-term tolerance), and UL94 V-0 flame retardant performance.

    Ultra-Long Life

    Designed for heavy-duty service with a lifespan exceeding 40 years indoors and over 30 years outdoors. Corrosion-resistant, anti-aging, with a smooth, aesthetic surface.

    Flexible Application

    Supports single-phase (220V) and three-phase (380V/690V) energy metering. Current coverage ranges from 10A to 250A. Adaptable for single-household, multi-household, or cross-household combinations.

    Environmental Adaptability

    Reliable operation within a temperature range of -25°C to +50°C and relative humidity ≤80% (at 40°C). IP44 protection rating ensures robust outdoor rainproof performance.

    Safety Specification

    Fully complies with GB standards. Features an insulation voltage of 800V and frequency compatibility with both 50Hz and 60Hz systems.

    Key Notes
    • The installation should be vertical (tilt ≤ 54°), away from corrosive chemicals (avoid strong alkali, ketones, and chlorinated hydrocarbons).
    • Avoid direct sunlight and mechanical collision; install in a dry and vibration-free environment.
    • During installation, remove the bottom screws first and fix the expansion tube according to the positioning holes.

    TY-SXS1-1H Model, configuration and installation dimensions

    TY SX S1 1 H
    Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Eighth Generation
    Configuration Name Component Model Quantity
    Incoming switch Disconnector HD11F-100/38 100A 1
    Outlet switch Leakage circuit breaker CDBLEK-125 4P li(C) 100A 1
    TY-SXS1-1H SMC Meter Box

    TY-SXS1-NX1 Model, configuration and installation dimensions

    TY SX S1 NX1
    Company Code SMC non-metallic metering box Three-phase single-meter metering box Ningxia
    Configuration Name Component Model Quantity
    Incoming switch Disconnector CDGK 4P 100A 1
    Outlet switch Miniature circuit breakers CDBKs C type 4P 63A dedicated to power grid 1
    TY-SXS1-NX1 SMC Meter Box

    TY-SXS1-1B Model, configuration and installation dimensions

    TY SX S1 1 B
    Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Second Generation
    Configuration Name Component Model Quantity
    Incoming switch Molded case circuit breaker CDMK-125C/3300 125A 1
    Outlet switch Leakage circuit breaker CDBLEK-125 4P li(C)100A 1
    TY-SXS1-1B SMC Meter Box

    TY-SXS1-1C Model, configuration and installation dimensions

    TY SX S1 1 C
    Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Third Generation
    Configuration Name Component Model Quantity
    Incoming terminal Disconnector HD11F-100/38 100A 1
    Outlet switch Leakage circuit breaker CDBLEK-125 4P li(C)100A 1
    TY-SXS1-1C SMC Meter Box

    TY-SXS1-1D Model, configuration and installation dimensions

    TY SX S1 1 D
    Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Fourth Generation
    Configuration Name Component Model Quantity
    Incoming switch Disconnector HD11F-200/48 200A 19CM 1
    Outlet switch Molded case circuit breaker CDMK-250C/3300 200A 1
    TY-SXS1-1D SMC Meter Box

    TY-SXS1-1E Model, configuration and installation dimensions

    TY SX S1 1 E
    Company Code SMC non-metallic metering box Three-phase single-meter metering box Table number Fifth Generation
    Configuration Name Component Model Quantity
    Incoming terminal Disconnector HD11F-200/48 200A 19CM 1
    Outlet switch Molded case circuit breaker CDMK-250C/3300 200A 1
    TY-SXS1-1E SMC Meter Box

    Frequently Asked Questions (FAQ)

    What are the core material advantages of the TY series fiberglass meter box?

    The TY series is molded from SMC glass fiber reinforced plastic, which provides high insulation (≥20MΩ), excellent impact resistance (30KA short-term tolerance), and UL94 V-0 flame retardant performance.

    What is the expected service life of these meter boxes in outdoor environments?

    Thanks to their corrosion-resistant and anti-aging properties, these meter boxes have a service life of over 30 years in outdoor environments and more than 40 years when installed indoors.

    What electrical configurations and voltage levels do the TY series support?

    They support single-phase (220V) and three-phase (380V/690V) energy metering with a current capacity ranging from 10A to 250A. The insulation voltage is rated up to 800V at 50/60Hz frequency.

    What are the critical environmental and installation requirements?

    The box should be installed vertically (tilt angle ≤ 54°) in a dry, vibration-free environment away from direct sunlight, mechanical collisions, and corrosive chemicals like strong alkalis, ketones, or chlorinated hydrocarbons. The ambient working temperature should be between -25°C and +50°C.

    How do I install the TY series meter box securely?

    When installing, you must first remove the screws located at the bottom of the enclosure and then fix the expansion tube securely according to the pre-marked positioning holes.