TY-SXD2 single-phase electric energy metering box(2-6)

A highlight of the TY-SXD2 series is that its main busbar rated current ranges from 250A to 10A. This flexibility makes it suitable for a variety of applications and can adapt to different load requirements while ensuring optimal performance. The main busbar is also designed to withstand short-term currents of up to 30KA, providing durability and reliability that are critical in high-demand environments. This feature not only enhances the safety of the electrical system, but also extends the service life of the meter box.

    Product Overview

    The TY series FRP electric energy metering boxes developed by Teyi Electric Co., Ltd. are made of SMC unsaturated polyester resin glass fiber reinforced plastics through compression molding. They have the characteristics of reliable insulation, high strength, good flame retardancy, corrosion resistance, aging resistance, novel shape, smooth and beautiful surface, etc. The service life is more than 40 years indoors and more than 30 years outdoors, which is incomparable to other metal plastic electric meter boxes. This product is widely used in residential construction and civil power transformation. It can be combined with multiple households at will, and can also be installed in a single household or across households. It is easy to construct and has concealed wiring. This product adopts a strict rainproof design and is suitable for outdoor installation to ensure the safe operation of the electric meter.

    Product use scope and conditions of use

    TY series electric energy metering box includes two parts: single-phase meter box and three-phase meter box. It is suitable for AC 50Hz or 60Hz, rated working voltage up to 220V, 380V, 690V, rated working current of 10A-250A power supply system, for single-phase electric energy and power energy measurement and control management.

    Conditions of use:

    ◆ The ambient temperature is -25℃ ~+50℃, and the average temperature within 24 hours does not exceed +35℃.

    ◆ The air should be clean, and the relative humidity should not exceed 80% at 40℃. Higher relative humidity is allowed when the temperature is lower.

    Product installation and use

    ◆ Please carefully check the integrity of all parts of the meter box during installation.

    ◆ The meter box should be installed vertically and the tilt angle should not exceed 54°.

    ◆ The installation location should be selected where there is no severe vibration, impact, or corrosion to electrical components.

    ◆ The material used in the meter box is not resistant to strong alkali, oxidizing acid, amine, ketone, and soluble in chlorinated hydrocarbons and aromatic solvents. Therefore, it should be avoided from contact or use with these chemicals. During use, sharp objects and hard objects should be avoided from colliding and scratching the surface of the meter box.

    ◆ When installing the meter box, try to choose a cool and dry place to avoid long-term direct sunlight to extend the service life of the meter.

    ◆ The fixing positions of the meter box for fixing on the wall or crossarm are all located inward, so the box must be opened before installation. First, remove the two upper cover fixing screws located in the middle of the lower part of the meter box, and then open the box according to the instructions here.

    ◆ According to the location of the installation holes, drill the installation holes at the corresponding positions of the wall, install the expansion tube, then fix the base to the wall and install the upper cover.

    Main technical parameters of the product

    ◆ Main bus rated current In: 250A-10A

    ◆ Main bus rated short-time withstand current low: 30KA

    ◆ Insulation resistance: not less than 20MΩ

    ◆ Rated insulation voltage UI: 800V

    ◆ Frequency: 50Hz or 60Hz

    ◆ Security protection level IP: 44

    TY-SXD2-2E Model, configuration and installation dimensions

    TY

    SX

    D2

    2

    E

    Company Code

    SMC non-metallic metering box

    Single-phase multi-meter metering box

    Table number

    Fifth Generation

     

    Configuration

    Name

    Component Model

    Quantity

    Incoming switch

    Molded case circuit breaker

    CDMK-125C/3300 125A

    1

    Outlet switch

    Leakage circuit breaker

    CDBLEK 2P C type 63A

    2

    TY-SXD2-2E.jpg

    TY-SXD2-3E Model, configuration and installation dimensions

    TY

    SX

    D2

    3

    E

    Company Code

    SMC non-metallic metering box

    Single-phase multi-meter metering box

    Table number

    Fifth Generation

     

    Configuration

    Name

    Component Model

    Quantity

    Incoming switch

    Molded case circuit breaker

    CDMK-125C/3300 125A

    1

    Outlet switch

    Leakage circuit breaker

    CDBLEK 2P C type 63A

    3

    TY-SXD2-3E.jpg

    TY-SXD2-4G Model, configuration and installation dimensions

    TY

    SX

    D2

    4

    G

    Company Code

    SMC non-metallic metering box

    Single-phase multi-meter metering box

    Table number

    Seventh Generation

     

    Configuration

    Name

    Component Model

    Quantity

    Incoming switch

    Disconnector

    HD11F-100/38 100A

    1

    breaker

    Molded case circuit breaker

    CDMK-125C/3300 100A

    1

    Outlet switch

    Miniature circuit breakers

    CDBKs C type 2P 63A dedicated to power grid

    4

    TY-SXD2-4G.jpg

    TY-SXD2-4H Model, configuration and installation dimensions

    TY

    SX

    D2

    4

    H

    Company Code

    SMC non-metallic metering box

    Single-phase multi-meter metering box

    Table number

    Eighth Generation

     

    Configuration

    Name

    Component Model

    Quantity

    Incoming switch

    Molded case circuit breaker

    CDMK-125C/3300 125A

    1

    Outlet switch

    Miniature circuit breakers

    CDBKs C type 2P 63A dedicated to power grid

    4

    TY-SXD2-4H.jpg

    TY-SXD2-6H Model, configuration and installation dimensions

    TY

    SX

    D2

    6

    H

    Company Code

    SMC non-metallic metering box

    Single-phase multi-meter metering box

    Table number

    Eighth Generation

     

    Configuration

    Name

    Component Model

    Quantity

    Incoming switch

    Molded case circuit breaker

    CDMK-125C/3300 125A

    1

    Outlet switch

    Miniature circuit breakers

    CDBKs C type 2P 63A dedicated to power grid

    6

    TY-SXD2-6H.jpg

    TY-SXD2-6L Model, configuration and installation dimensions

    TY

    SX

    D2

    6

    L

    Company Code

    SMC non-metallic metering box

    Single-phase multi-meter metering box

    Table number

    The 12th Generation

     

    Configuration

    Name

    Component Model

    Quantity

    Incoming switch

    Molded case circuit breaker

    CDMK-125C/3300 125A

    1

    Outlet switch

    Miniature circuit breakers

    CDBKs C type 2P 63A dedicated to power grid

    6

    TY-SXD2-6L.jpg

    TY-SXD2-6J Model, configuration and installation dimensions

    TY

    SX

    D2

    6

    J

    Company Code

    SMC non-metallic metering box

    Single-phase multi-meter metering box

    Table number

    Tenth Generation

     

    Configuration

    Name

    Component Model

    Quantity

    Incoming switch

    Molded case circuit breaker

    CDMK-125C/3300 125A

    1

    Outlet switch

    Miniature circuit breakers

    CDBKs C type 2P 63A dedicated to power grid

    6

    TY-SXD2-6J.jpg

    TY-SXD2-6G Model, configuration and installation dimensions

    TY

    SX

    D2

    6

    G

    Company Code

    SMC non-metallic metering box

    Single-phase multi-meter metering box

    Table number

    Seventh Generation

     

    Configuration

    Name

    Component Model

    Quantity

    Incoming switch

    Molded case circuit breaker

    CDMK-125C/3300 125A

    1

    Outlet switch

    Miniature circuit breakers

    CDBKs C type 2P 63A dedicated to power grid

    6

    Power supply

    breaker

    CDBK C type 2P 6A

    1

    TY-SXD2-6G.jpg