The TY-TTU series intelligent fusion terminal box is designed for easy and efficient installation while ensuring optimal performance for power systems. To begin the installation process, open the junction box and position it so that the fixing part faces inward towards the wall or cross arm. Start by removing the two upper cover fixing screws located at the bottom center of the meter box. Once accessed, follow the provided instructions to open the junction box properly. Proceed by drilling mounting holes in the designated wall areas and inserting expansion tubes for stability. Finally, secure the base of the junction box to the wall, replace the upper cover, and your installation will be complete. By adhering to these guidelines, users will successfully install the TY-TTU-1T/TY-TTU-2T intelligent fusion terminal, enhancing both the performance and reliability of their power systems. As a leading supplier and factory in China, we are committed to providing high-quality products that meet the demands of modern electrical infrastructure

    Product Overview

    The TY series FRP electric energy metering boxes developed by Teyi Electric Co., Ltd. are made of SMC unsaturated polyester resin glass fiber reinforced plastics through compression molding. They have the characteristics of reliable insulation, high strength, good flame retardancy, corrosion resistance, aging resistance, novel shape, smooth and beautiful surface, etc. The service life is more than 40 years indoors and more than 30 years outdoors, which is incomparable to other metal plastic electric meter boxes. This product is widely used in residential construction and civil power transformation. It can be combined with multiple households at will, and can also be installed in a single household or across households. It is easy to construct and has concealed wiring. This product adopts a strict rainproof design and is suitable for outdoor installation to ensure the safe operation of the electric meter.

    Product Use Scope and Conditions of Use

    TY series electric energy metering box includes two parts: single-phase meter box and three-phase meter box. It is suitable for AC 50Hz or 60Hz, rated working voltage up to 220V, 380V, 690V, rated working current of 10A-250A power supply system, for single-phase electric energy and power energy measurement and control management.

    Conditions of use:

    • The ambient temperature is -25℃ ~+50℃, and the average temperature within 24 hours does not exceed +35℃.
    • The air should be clean, and the relative humidity should not exceed 80% at 40℃. Higher relative humidity is allowed when the temperature is lower.

    Product Installation and Use

    • Please carefully check the integrity of all parts of the meter box during installation.
    • The meter box should be installed vertically and the tilt angle should not exceed 54°.
    • The installation location should be selected where there is no severe vibration, impact, or corrosion to electrical components.
    • The material used in the meter box is not resistant to strong alkali, oxidizing acid, amine, ketone, and soluble in chlorinated hydrocarbons and aromatic solvents. Therefore, it should be avoided from contact or use with these chemicals. During use, sharp objects and hard objects should be avoided from colliding and scratching the surface of the meter box.
    • When installing the meter box, try to choose a cool and dry place to avoid long-term direct sunlight to extend the service life of the meter.
    • The fixing positions of the meter box for fixing on the wall or crossarm are all located inward, so the box must be opened before installation. First, remove the two upper cover fixing screws located in the middle of the lower part of the meter box, and then open the box according to the instructions here.
    • According to the location of the installation holes, drill the installation holes at the corresponding positions of the wall, install the expansion tube, then fix the base to the wall and install the upper cover.

    Main Technical Parameters of the Product

    Main Bus Rated Current In
    250A-10A
    Rated Short-time Withstand Current
    30KA
    Insulation Resistance
    Not less than 20MΩ
    Rated Insulation Voltage UI
    800V
    Frequency
    50Hz or 60Hz
    Security Protection Level IP
    44

    Appearance and Installation Dimensions

    Frequently Asked Questions (FAQ)

    What material is used for the TY series electric energy metering boxes?
    The TY series FRP electric energy metering boxes are made of SMC unsaturated polyester resin glass fiber reinforced plastics through compression molding. This material provides reliable insulation, high strength, and excellent flame retardancy.
    What is the expected service life of these meter boxes?
    The service life of the TY series metering boxes is more than 40 years for indoor installations and more than 30 years for outdoor installations.
    Are the TY series meter boxes suitable for outdoor installation?
    Yes, these boxes adopt a strict rainproof design and are highly suitable for outdoor installation, ensuring the safe and reliable operation of the electric meter inside.
    What are the recommended temperature and humidity conditions for use?
    The operating ambient temperature should be between -25℃ and +50℃ (with a 24-hour average not exceeding +35℃). The relative humidity should not exceed 80% at 40℃, though higher relative humidity is allowed at lower temperatures.
    What chemicals should be kept away from the meter box?
    The SMC material used in the meter box is not resistant to strong alkalis, oxidizing acids, amines, and ketones. It is also soluble in chlorinated hydrocarbons and aromatic solvents, so contact with these chemicals must be avoided.
    What is the security protection level and rated insulation voltage?
    The TY series metering box has a security protection rating of IP44 and a rated insulation voltage (UI) of 800V.